Smith & Nephew
US Professional

Smith & Nephew Corporate

|

Select your country

Smith & Nephew

Advanced Search
  • Home
  • Products
  • Training and Education
  • Resources
  • News & Careers
  • US Professional Home
  • Products
  • All Products
  • GTS SYSTEM
  • US Professional Home >
  • Products >
  • All Products >
  • GTS SYSTEM
  • All Products
  • Featured Products
  • Whats New
  • Wound measurement
  • Visualization / Image Management
  • Wound Bed Preparation
  • Surgical / Post Operative Wounds
  • Shoulder Replacement
  • Skincare/prevention
  • Scars
  • Resorbable Scaffolds
  • Resection
  • Pressure Ulcers
  • Plates & Screws
  • Palliative Care
  • Pain Management
  • Negative Pressure Wound Therapy
  • Leg Ulcers
  • Laparoscopy
  • Knee Replacement
  • Joint Resurfacing
  • Joint Repair
  • IV Site Care
  • Internal Fixation
  • Hip Replacement
  • Gynecology
  • Grafts/Dermal substitutes
  • External Fixation
  • Donor Sites
  • Diabetic Foot Ulcers
  • Deformity Correction
  • Computer Assisted Surgery
  • Burns
  • Biomaterials
  • Access / Fluid Management
  • Clinical Therapies
  • Contact
  • Print
  • Forward

Email this page

close
  1. Mandatory fields are marked with an asterisk [*].

    Tell us who you want to send your mail to Fill in your email details

    Note: Smith & Nephew does not collect or make use of the email addresses or names provided here. They are only used to show the recipient who has sent the message.

    Change your message if you want Change the message if you want to

    1. <recipient name> <address>
    2. <sender name> <address>
    3. <sender name> is sending you a link

    4. <sender name>

    Visitor verification

    Validating...
Email sent successfully
Error: Check all fields are valid. Exclude special characters from Comments field
Smith
Nephew

GTS SYSTEM

Graft Tunnel Solutions

View list of all products

You may also be interested in:

WHIPKNOT  Soft Tissue Cinch
  • WHIPKNOT◊ Soft Tissue Cinch
  • ACUFEX◊ Anatomic ACL Guide System
  • BIORCI◊ Bioabsorbable Screw System
  • ENDOBUTTON◊ CL BTB Fixation Device
  • XTENDOBUTTON◊ Fixation Device
  • DYONICS◊ Arthroscopic Resection System
  • DYONICS◊ Fluid Management System
  • 560 Series High Definition Camera System
  • Overview
  • Overview
  • Ordering Information
  • Technique Information

Ligament repair made simple

The Smith & Nephew GTS SYSTEM offers technologically advanced instruments to assist surgeons during ACL reconstruction procedures. More than just a means of simplifying the technique, this system is able to effectively anchor and compress soft tissue grafts, giving surgeons the confidence of a strong, accurate fixation.


GTS Sleeve

GTSSystemGraftTunnelSolutions_Overview_Sleeve  
A non-absorbable, three-lumen woven mesh sleeve that provides ultimate pullout strength above 1,000N and a stiffness of 100N/mm. The bottom lumens are used to house each strand of the Gracilis ligament, while the central lumen houses the GTS Tapered Screw once the graft is positioned and tensioned within the tibial tunnel. Surrounding the sleeve is a Type 0, braided, polyester cinching suture.


GTS Tapered Screw

 GTSSystemGraftTunnelSolutions_Overview_TaperedScrew
Available in sizes 7-9 mm x 30 mm and 8-10 mm x 30 mm, this absorbable screw made from PLLA is inserted into the central lumen of the GTS sleeve to enable fixation of the sleeve and graft. Because it is designed with a shorter pitch and closer thread, the GTS screw provides higher compression at the site once it is implanted.

GRAFTMASTER◊ II Preparation Board, ENDOBUTTON◊ Holder with Extender, and Graft Tensioning Device Holder

GTSSystemGraftTunnelSolutions_Overview_Graftmaster
Used to position the GTS sleeve in the correct area of the graft so that maximum fixation strength will be obtained once the graft is inserted into the tunnel. Positioning the GTS sleeve involves the use of threading tubes for each Gracilis ligament strand as well as the Graft Tensioning Device, which provides equal tension of all four ligament strands while the graft is being prepared.

ENDOBUTTON◊ Depth Gauge Probe Locator

Used to measure the overall length of the tibial and femoral tunnels prepared during the first step of the procedure. This measurement determines where the GTS Sleeve will be placed on the graft prior to its insertion into the tunnel. The probe locator knob is a retro-fit device that can be purchased separately.


WHIPKNOT◊ Soft Tissue Cinch

 GTSSystemGraftTunnelSolutions_Overview_Whipknot
Eliminates the need for whip stitching during graft preparation. WHIPKNOT◊ offers a pre-tied knot that can easily be placed on a graft strand through use of a pre-loaded cannula.


Graft Tensioning Device

 GTSSystemGraftTunnelSolutions_Overview_GraftTensioningDevice
Features four adjustable knobs that capture suture strands and apply equal tension to soft tissue grafts during graft preparation. It can also be used at the knee during the procedure to keep distal strands of the graft separate and in line with the tibial tunnel.

  • ◊ Trademark of Smith & Nephew | This information intended for United States customers only
  • Accessibility
  • Copyright & Disclaimer